| Global Variables | |
|---|---|
| %Code_Factors_FLA% | MCC Code Factors Load FLA (Including Downstream Load), Summary tab |
| %Code_Factors_kVA% | MCC Code Factors Load kVA (Including Downstream Load), Summary tab |
| %Connected_FLA% | Connected MCC Load FLA, Summary tab |
| %Connected_HP% | Connected MCC Load Motor HP, Summary tab |
| %Connected_kVA% | Connected MCC Load kVA, Summary tab |
| %Demand_FLA% | Demand MCC Load FLA, Summary tab |
| %Demand_kVA% | Demand MCC Load kVA, Summary tab |
| %Aic% | SC Rating (kA), Specifications Tab (Bus Rating section) |
| %Amps% | Horz Bus Rating (A), Specifications Tab |
| %Location% | Location, Specifications Tab |
| %Main% | Main Incoming Device Amps (A), MCC/Panel Incoming Tab |
| %Service% | Service, MCC/Panel Specifications Tab |
| %EasyPower_Version% | EasyPower Version |
| %FileName% | File Name |
| %Name% | Equipment ID Name |
| %ProjectName% | Project Name, located in File Properties |
| %Voltage% | Base Voltage (V) |
| %Mounting% |
Mounting |
| %Panel_Description% | Panel Description |
| %ProjectCode% | Project Code |
| %Connected_Subfed_Total_VA% | Subfed Total VA |
| %AverageConnectedAmps% | Average Connected Amps Based on Total Connected Load |
| %AverageCodeAmps% | Average Connected Amps Based on Total Demand Load |
| Short Circuit (stored on fault) | |
|---|---|
| %sc_sym_a% | Short Circuit Sym A |
| %mcc_sym_ka% | Lowest Rated Equipment kA, Description tab |
| Arc Flash | |
|---|---|
| %afh_incident_energy% | Incident Energy (cal/cm2), Summary tab |
| %afh_boundary% | Estimated Arc Flash Boundary (inches), Summary tab |
| %afh_working_distance% | Arc Flash Working Distance (inches) |
| %afh_ppe% | Arc Flash PPE, Summary tab |
| Grid | |
|---|---|
| %CondNoPh% | Conductor No/Ph, Description tab |
| %CondSize% | Conductor Size, Description tab |
| %CondType% | Conductor Type, Description tab |
| %EquipmentName% | Equipment Name, Description tab |
| %HPkW% | Motor HP (rounded to nearest whole number), Description tab |
| %IntkA% | Protective Device Int kA, Description tab |
| %MotorkV% | Motor kV, MCC Description tab |
| %NEMACode% | Motor NEMA Code, MCC Description tab |
| %StatickV% | Static Load kV, MCC Description tab |
| %StatickVAR% | Static Load kVAR, MCC Description tab |
| %StatickW% | Static Load kW, MCC Description tab |
| %TripA% | Protective Device Trip Amps, Description tab |
| %SectionSpace% | Section Space, Description tab |
| %Description% | Load Description, Description tab |
| Accessories Tab | |
| %AccessoryName% | Accessory Name |
| %meterKVA% | Meter KVA |
| %meterMaxDemand% | Maximum Demand |
| %meterReadingDate% | Reading Date |
| %meterNote% | Metering Note |
| %meterSafetyFactor% | Safety Factor |
| %meterLoadWithSafetyFactor% | Meter Load with Safety Factor |
| %meterNewDemandLoad% | Added New Demand Load |
| %meterTotalNewDemandLoad% | Total New Demand Load |
| %meterTotalAmps% | Total Amps |
| %meterPowerFactor% | Power Factor |
| Code Factors (by Demand Factor) | |
| %cfLevel1Header% | Code Factor Name |
| %cfConnectedLevel1% | Connected Load up to Demand Factor 1 |
| %cfDownStreamLevel1% | Downstream Load up to Demand Factor 1 |
| %cfTotalLevel1% | Total Load up to Demand Factor 1 |
| %cfCodeFactor1% | Code Factor of Demand Factor 1 |
| %cfFactoredTotalLevel1% | Total Code Factor of Demand Factor 1 |
| %cfLevel2Header% | Code Factor Name |
| %cfConnectedLevel2% | Connected Load up to Demand Factor 2 |
| %cfDownStreamLevel2% | Downstream Load up to Demand Factor 2 |
| %cfTotalLevel2% | Total Load up to Demand Factor 2 |
| %cfCodeFactor2% | Code Factor of Demand Factor 2 |
| %cfFactoredTotalLevel2% | Total Code Factor of Demand Factor 2 |
| %cfLevel3Header% | Code Factor Name |
| %cfConnectedLevel3% | Connected Load up to Demand Factor 3 |
| %cfDownStreamLevel3% | Downstream Load up to Demand Factor 3 |
| %cfTotalLevel3% | Total Load up to Demand Factor 3 |
| %cfCodeFactor3% | Code Factor of Demand Factor 3 |
| %cfFactoredTotalLevel3% | Total Code Factor of Demand Factor 3 |
| Schedule Variables | |
| Schedules |
|