| Global Variables | |
| %BusRating% | Bus Rating (A), "Rating" Field in Specifications Tab |
| %SCCR% | Bracing (kA), Specifications Tab |
| %SwgUnits% | Specified Units ("kVA" or "Amps"), Switchgear Tab |
| %SwitchType% | Bus Type ("Type" field in Specifications tab), "Switchgear" |
| %EasyPower_Version% | EasyPower Version |
| %FileName% | File Name |
| %Name% | Equipment ID Name |
| %ProjectName% | Project Name, located in File Properties |
| %TotalCodeAmps% | Total Downstream Code Factor Load (Amps), see Switchgear tab |
| %TotalCodeVA% | Total Downstream Code Factor Load (VA), see Switchgear tab |
| %TotalConnAmps% | Total Downstream Connected Load (Amps), see Switchgear tab |
| %TotalConnVA% | Total Downstream Connected Load (VA), see Switchgear tab |
| %TotalDemandAmps% | Total Downstream Demand Load (Amps), see Switchgear tab |
| %TotalDemandVA% | Total Downstream Demand Load (VA), see Switchgear tab |
| %TotalDesignAmps% | Total Downstream Design Load (Amps), see Switchgear tab |
| %TotalDesignVA% | Total Downstream Design Load (VA), see Switchgear tab |
| %Voltage% | Base Voltage (V) |
| %Mounting% |
Mounting |
| %Panel_Description% | Panel Description |
| %ProjectCode% | Project Code |
| %Main% | Main Lug or Breaker |
| %Connected_Subfed_Total_VA% | Subfed Total VA |
| %AverageConnectedAmps% | Average Connected Amps Based on Total Connected Load |
| %AverageCodeAmps% | Average Connected Amps Based on Total Demand Load |
| Short Circuit | |
| %sc_sym_a% | Short Circuit Sym A, Summary tab |
| Arc Flash | |
|---|---|
| %afh_incident_energy% | Incident Energy (cal/cm2), Summary tab |
| %afh_boundary% | Estimated Arc Flash Boundary (inches), Summary tab |
| %afh_working_distance% | Arc Flash Working Distance (inches) |
| %afh_ppe% | Arc Flash PPE, Summary tab |
| Grid | |
| %BrkrMfg% | Breaker Manufacturer |
| %BrkrStyle% | Breaker Style |
| %CondRating% | Conductor Rating (A), Switchgear tab |
| %DeviceRating% | Device Rating (A), Switchgear tab |
| %FeederID% | "ID Name" column, Switchgear tab |
| %GridRow% | Row Number, Switchgear tab |
| %SectionSpace% | "Section Space" column, Switchgear tab |
| %TripMfg% | Trip Device Manufacturer |
| %TripPlug% | Trip Device Plug |
| %TripSensor% | Trip Device Sensor |
| %TripStyle% | Trip Device Style |
| %Description% | "Description" column, Switchgear tab |
| %Type% | "Device" column, Switchgear tab |
| Accessories Tab | |
| %AccessoryName% | Accessory Name |
| %meterKVA% | Meter KVA |
| %meterMaxDemand% | Maximum Demand |
| %meterReadingDate% | Reading Date |
| %meterNote% | Metering Note |
| %meterSafetyFactor% | Safety Factor |
| %meterLoadWithSafetyFactor% | Meter Load with Safety Factor |
| %meterNewDemandLoad% | Added New Demand Load |
| %meterTotalNewDemandLoad% | Total New Demand Load |
| %meterTotalAmps% | Total Amps |
| %meterPowerFactor% | Power Factor |
| Code Factors | |
| %cfRow% | Code Factor Row Number |
| %cfName% | Code Factor Name |
| %cfPhase1% | Aph (VA) |
| %cfPhase2% | Bph (VA) |
| %cfPhase3% | Cph (VA) |
| %cfPhaseRowTotal% | Phase Row Total (VA), Aph + Bph + Cph |
| %cfPhaseTotal% | Calculated Phase Total |
| Code Factors (by Demand Factor) | |
| %cfLevel1Header% | Code Factor Name |
| %cfConnectedLevel1% | Connected Load up to Demand Factor 1 |
| %cfDownStreamLevel1% | Downstream Load up to Demand Factor 1 |
| %cfTotalLevel1% | Total Load up to Demand Factor 1 |
| %cfCodeFactor1% | Code Factor of Demand Factor 1 |
| %cfFactoredTotalLevel1% | Total Code Factor of Demand Factor 1 |
| %cfLevel2Header% | Code Factor Name |
| %cfConnectedLevel2% | Connected Load up to Demand Factor 2 |
| %cfDownStreamLevel2% | Downstream Load up to Demand Factor 2 |
| %cfTotalLevel2% | Total Load up to Demand Factor 2 |
| %cfCodeFactor2% | Code Factor of Demand Factor 2 |
| %cfFactoredTotalLevel2% | Total Code Factor of Demand Factor 2 |
| %cfLevel3Header% | Code Factor Name |
| %cfConnectedLevel3% | Connected Load up to Demand Factor 3 |
| %cfDownStreamLevel3% | Downstream Load up to Demand Factor 3 |
| %cfTotalLevel3% | Total Load up to Demand Factor 3 |
| %cfCodeFactor3% | Code Factor of Demand Factor 3 |
| %cfFactoredTotalLevel3% | Total Code Factor of Demand Factor 3 |
| Schedule Variables | |
| Schedules |
|