Generator Models

Round Rotor Generator

The round rotor generator necessitates the following parameters:

Parameter

 Units

Description

Rated MVA

MVA

 

Rated Efficiency

Percent

 

Rated Speed

RPM

 

Rated Voltage

Volts LL

 

Rated Current

Amps

 

Rated PF

 

 

Ra

pu

Armature Resistance

Xd

pu

D-Axis Synchronous Reactance

Xq

pu

Q-Axis Synchronous Reactance

X’d

pu

D-Axis Transient Reactance

X’q

pu

Q-Axis Transient Reactance

X’’d = X’’q

pu

D & Q-Axis Sub-Transient Reactance

Xl

pu

Stator Leakage Reactance

T’do

Seconds

D-Axis Transient OC Time Constant

T’qo

Seconds

Q-Axis Transient OC Time Constant

T’’do

Seconds

D-Axis Sub-Transient OC Time Constant

T’’qo

Seconds

Q-Axis Sub-Transient OC Time Constant

E1

pu

First Voltage to Define Saturation

E2

pu

Second Voltage to Define Saturation

S( E1 )

pu

Saturation at E1

S( E2 )

pu

Saturation at E2

H

kW-Sec / kVA

Combined machine and prime mover inertia

D

pu

Machine damping, normally = 0

Note: OC = Open Circuit.

These are standard machine quantities, and are based upon a sub-transient level detail flux model. All machine data shown above is mandatory for modeling the round rotor generator properly.

Salient Pole Generator

The salient pole generator necessitates the following parameters:

Parameter

Units

Description

Rated MVA

MVA

 

Rated Eff

Percent

 

Rated Speed

RPM

 

Rated Voltage

Volts LL

 

Rated Current

Amps

 

Rated PF

 

 

Ra

pu

Armature Resistance

Xd

pu

D-Axis Synchronous Reactance

Xq

pu

Q-Axis Synchronous Reactance

X’d

pu

D-Axis Transient Reactance

X’’d

pu

D-Axis Sub-Transient Reactance

Xl

pu

Stator Leakage Reactance

T’do

Seconds

D-Axis Transient OC Time Constant

T’’do

Seconds

D-Axis Sub-Transient OC Time Constant

T’’qo

Seconds

Q-Axis Sub-Transient OC Time Constant

E1

pu

First Voltage to Define Saturation

E2

pu

Second Voltage to Define Saturation

S( E1 )

pu

Saturation at E1

S( E2 )

pu

Saturation at E2

H

kW-Sec / kVA

Combined machine and prime mover inertia

D

pu

Machine damping, normally = 0

Note: OC = Open Circuit.

Again, these are standard machine quantities, and are based upon a sub-transient level detail flux model. All machine data shown above is mandatory for modeling the salient pole generator properly.

More Information

Dynamic Stability  
Stability Data Parameters  
     

www.easypower.com

EasyPower, LLC

7730 SW Mohawk St.

Tualatin, OR 97062

(503)655-5059

techsupport@easypower.com

feedback@easypower.com

EasyPower knowledge base

EasyPower Version 10.0

Copyright © 2018 EasyPower, LLC. All Rights Reserved.

Help was last updated on 5/22/2018