10.0 SP2 Release Notes
EasyPower 10.0 Service Pack 2 includes the following minor product enhancements and bug fixes.
Arc Flash
- Fixed an issue where older .DEZ files that were opened in version 10.0 were not displaying arc flash results.
Coordination
- Fixed an issue in Coordination where the ground curve did not display in the TCC plot when switching from 3-phase to single-line-to-ground faults.
- Fixed an issue where fuse curves did not appear on a TCC plot.
- Fixed an issue where one-line equipment for TCC printouts were left-aligned instead of centered when printing to PDF.
- Fixed an issue where the Auto Coordination Phase Report did not show the correct original STPU settings on certain breakers after using the auto-coordinate feature.
- Fixed an issue where closing the SmartPDC Report also closed the one-line.
- Added a message that appears on the Auto Coordination reports when you attempt to auto coordinate SST devices with multiple long term delay curves, which are not currently supported.
- Fixed an issue where stored TCC's lost their tick mark settings after closing and reopening the stored TCC.
-
Fixed an issue where certain breakers incorrectly displayed a straight curve on the TCC plot when the short time pickup was increased.
-
Fixed an issue where TCC curves were plotted for protective devices even though the plot TCC check box was not selected in the data dialog box.
Drawings
- Fixed an issue where cable data did not appear in some drawings due to text visibility settings being applied incorrectly.
-
Fixed an issue where EasyPower reported an internal issue when you attempted to move a cable in a drawing.
Equipment Data
- Fixed an issue where changes made in the elevation view of the MCC Data dialog box were not being displayed or saved.
Export to DXF
- Fixed an issue where when exporting a drawing to DXF resulted in arrows for the current direction not being displayed.
- Fixed an issue where exporting multiple drawings into a single DXF file caused the drawings to overlap.
- Fixed an issue where exporting to DXF would cause EasyPower to stop responding when customized one-line text exceeded 100 characters or included more than 6 lines of text.
Harmonics
- Restored the ability to see data on harmonics bar charts when hovering the pointer over the bar chart.
Imported Data
- Fixed an issue where importing data when the import file had duplicate names caused EasyPower to close without completing the import. Now, it displays a warning message.
- Fixed issue where EasyPower closed when attempting to import .CSV files due to ID names being truncated.
One-line Display and Printing
- Fixed an issue where the number of phases and phasing data text for an ATS was displayed too closely to the equipment name.
- Fixed an issue where text in an MCC symbol word-wraps when printing a one-line but not when viewing the one-line.
Performance
- Fixed an issue where EasyPower was slow to start up due to performance issues related to a Windows 10 update.
Program
- Fixed an issue where missing image files caused EasyPower to close and then display a database error message after the .DEZ file was reopened and a copy/paste action was attempted.
- Fixed an issue where EasyPower closed unexpectedly while saving the one-line due to the way a deleted temporary file was being handled.
Reports
- Enhanced the Equipment Duty report to include Manufacturer and Type columns for buses.
Settings
- Fixed an issue where the last stored database was not opened when the Reload database on startup option was selected.
- Fixed an issue where EasyPower was not properly adjusting DPI scaling to match monitor settings when multiple monitors were being used.
Schedules
- Fixed issues where Other Motor load values were not showing in customized schedules.
Short Circuit
- Fixed an issue where system components that were disconnected and then reconnected did not allow the Short Circuit focus to be opened due to an erroneously reported isolated system error.
Transient Motor Starting
- Enhanced the descriptions for Transient Motor Starting functions in situations where the Dynamic Stability feature has not been purchased. Previously, Dynamic Stability terminology was used in the program, which could potentially create confusion.
Undo
- Fixed an issue where disconnecting equipment and then undoing the disconnect would cause EasyPower to display an error after opening a drawing.
- Fixed an issue where disconnecting a cable and then undoing the disconnect would cause EasyPower to stop responding.
More Information
| EasyPower 10.0 Release Details |