Panel Variables

See also Panel Summary Tab Variables and Code Factor Variables.

General

These variables are available to all schedule templates.

Variables

%Current_Date_Time%

Format: "MM/DD/YYYY HH:MM:SS"

%EasyPower_Version%

EasyPower version

%FileName%

File name

%ProjectCode%

Project Code in File Properties

%ProjectName%

Project Name in File Properties

Abbreviations

These variables enable you to use abbreviations in your schedules. See Abbreviations in Schedule Load Types for more information.

Variables
%ShortName% Short Name
%TargetName% Long Name

Accessories

These variables display information from the table on the Accessories tab.

Variables

%AccessoryName%

Accessory name

%row%

Row number

%meterKVA%

Accessories tab

%meterLoadWithSafetyFactor%

Accessories tab

%meterMaxDemand%

Accessories tab

%meterNewDemandLoad%

Accessories tab

%meterNote%

Accessories tab

%meterPowerFactor%

Accessories tab

%meterReadingDate%

Accessories tab

%meterSafetyFactor%

Accessories tab

%meterTotalAmps%

Accessories tab

%meterTotalNewDemandLoad%

Accessories tab

Equipment

These variables display information from the various tabs in the equipment data dialog boxes.

Variables

%afh_boundary%

Estimated Arc Flash Boundary (inches), Summary tab, from the last fault and store

%afh_incident_energy%

Incident Energy (cal/cm2), Summary tab, from the last fault and store

%afh_ppe%

Arc Flash PPE, Summary tab, from the last fault and store

%afh_working_distance%

Arc Flash Working Distance (inches), from the last fault and store

%Aic%

SC Rating (kA), Specifications tab (Bus Rating section)

%Amps%

Panel - main bus rating (A); MCC - horizontal bus rating (A)

%Area%

Area

%AverageCodeAmps%

Average Connected Amps Based on Total Demand Load

%AverageConnectedAmps%

Average Connected Amps Based on Total Connected Load

%BusRating%

Bus rating (A)

%Code_Factor_I%

Panel Summary tab

%Code_Factor_VA%

Panel Summary tab

%CodeAmps%

Panel Summary tab

%CodeVA%

Panel Summary tab

%Comment%

Comments tab

%ConnAmps%

Panel Summary tab

%Connected_A_I%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Connected_A_PF%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Connected_A_VA%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Connected_A_Vars%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Connected_A_Watts%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Connected_B_I%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_B_PF%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_B_VA%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_B_Vars%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_B_Watts%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_C_I%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_C_PF%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_C_VA%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_C_Vars%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_C_Watts%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Connected_1_I%

Reports the first phase (may be A, B, or C)

%Connected_1_PF%

Reports the first phase (may be A, B, or C)

%Connected_1_VA%

Reports the first phase (may be A, B, or C)

%Connected_1_Vars%

Reports the first phase (may be A, B, or C)

%Connected_1_Watts%

Reports the first phase (may be A, B, or C)

%Connected_2_I%

Reports the second phase (may be A, B, C or blank)

%Connected_2_PF%

Reports the second phase (may be A, B, C or blank)

%Connected_2_VA%

Reports the second phase (may be A, B, C or blank)

%Connected_2_Vars%

Reports the second phase (may be A, B, C or blank)

%Connected_2_Watts%

Reports the second phase (may be A, B, C or blank)

%Connected_3_I%

Reports the third phase (may be C or blank)

%Connected_3_PF%

Reports the third phase (may be C or blank)

%Connected_3_VA%

Reports the third phase (may be C or blank)

%Connected_3_Vars%

Reports the third phase (may be C or blank)

%Connected_3_Watts%

Reports the third phase (may be C or blank)

%Connected_Subfed_Total_Amps%

Subfed Total Amps

%Connected_Subfed_Total_VA%

Subfed Total VA

%Connected_Total_I%

Panel Summary tab

%Connected_Total_PF%

Panel Summary tab

%Connected_Total_VA%

Panel Summary tab

%Connected_Total_Vars%

Panel Summary tab

%Connected_Total_Watts%

Panel Summary tab

%ConnectedPhaseA_KVA%

 

%ConnectedPhaseB_KVA%

 

%ConnectedPhaseC_KVA%

 

%ConnectedTotal_KVA%

 

%ConnVA%

Panel Summary tab

%Demand_A_I%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Demand_A_PF%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Demand_A_VA%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Demand_A_Vars%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Demand_A_Watts%

Panel Summary tab (changed in 10.4 to always report "A" phase, not first phase)

%Demand_B_I%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Demand_B_PF%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Demand_B_PF%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Demand_B_Vars%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Demand_B_Watts%

Panel Summary tab (changed in 10.4 to always report "B" phase, not second phase)

%Demand_C_I%

Panel Summary tab (changed in 10.4 to always report "C" phase, not third phase)

%Demand_C_PF%

Panel Summary tab (changed in 10.4 to always report "C" phase, not third phase)

%Demand_C_VA%

Panel Summary tab (changed in 10.4 to always report "C" phase, not third phase)

%Demand_C_Vars%

Panel Summary tab (changed in 10.4 to always report "C" phase, not third phase)

%Demand_C_Watts%

Panel Summary tab (changed in 10.4 to always report "C" phase, not third phase)

%Demand_1_I%

Reports the first phase (may be A, B, or C)

%Demand_1_PF%

Reports the first phase (may be A, B, or C)

%Demand_1_VA%

Reports the first phase (may be A, B, or C)

%Demand_1_Vars%

Reports the first phase (may be A, B, or C)

%Demand_1_Watts%

Reports the first phase (may be A, B, or C)

%Demand_2_I%

Reports the second phase (may be A, B, C or blank)

%Demand_2_PF%

Reports the second phase (may be A, B, C or blank)

%Demand_2_VA%

Reports the second phase (may be A, B, C or blank)

%Demand_2_Vars%

Reports the second phase (may be A, B, C or blank)

%Demand_2_Watts%

Reports the second phase (may be A, B, C or blank)

%Demand_3_I%

Reports the third phase (may be C or blank)

%Demand_3_PF%

Reports the third phase (may be C or blank)

%Demand_3_VA%

Reports the third phase (may be C or blank)

%Demand_3_Vars%

Reports the third phase (may be C or blank)

%Demand_3_Watts%

Reports the third phase (may be C or blank)

%Demand_Total_I%

Panel Summary tab

%Demand_Total_PF%

Panel Summary tab

%Demand_Total_VA%

Panel Summary tab

%Demand_Total_Vars%

Panel Summary tab

%Demand_Total_Watts%

Panel Summary tab

%DemandAmps%

Panel Summary tab

%DemandVA%

Panel Summary tab

%Design_I%

Panel Summary tab

%Design_VA%

Panel Summary tab

%DesignAmps%

Panel Summary tab

%DesignCapacity%

 

%DesignRating%

 

%DesignVA%

Panel Summary tab

%Enclosure%

Enclosure, Specifications tab

%Fed_By%

Fed By, Specifications tab

%Header_Comment%

Header Comment, Specifications tab

%IncomingFeederConductorRating%

Incoming tab

%IncomingFeederTripAmps%

Incoming tab

%IncomingFeederTripDevice%

Incoming tab

%IncomingFrameLTPU%

Incoming tab

%IncomingFramePlug%

Incoming tab

%IncomingMfr%

Incoming tab

%IncomingPlugLTPU%

Incoming tab

%IncomingRating%

Incoming tab

%IncomingStyle%

Incoming tab

%Location%

Location, Specifications tab

%Main%

Main Incoming Device Type, Incoming tab

%MainDeviceTripAmps%

Main Incoming Device Trip Amps (A) - based on LTPU

%MainRating%

Main Incoming Device Frame Amps

%Manufacturer%

Manufacturer, Specifications tab (Bus Rating section)

%Material%

Specifications tab

%Mounting%

Mounting, Specifications tab

%Name%

Equipment ID Name

%Panel_Description%

Panel Description

%Panel_Rating_kA%

Lowest Rated Equipment kA (in Description tab)

%PhaseLabel1%

A, B, or C, depending on phase type

%PhaseLabel2%

A, B, or C, depending on phase type

%PhaseLabel3%

A, B, or C, depending on phase type

%RatingType%

 

%sc_sym_a%

Short Circuit Symmetrical A

%sc_sym_ka%

Short Circuit Symmetrical kA

%SCCR%

Bracing (kA), Specifications tab

%Service%

Service, MCC/Panel Specifications tab

%SwgUnits%

Specified Units (kVA or Amps)

%SwitchType%

Bus Type (Type in Specifications tab)

%TotalCodeAmps%

Total Downstream Code Factor Load (Amps)

%TotalCodeVA%

Total Downstream Code Factor Load (VA)

%TotalConnAmps%

Total Downstream Connected Load (Amps)

%TotalConnAverageAmps%

 

%TotalConnVA%

Total Downstream Connected Load (VA)

%TotalDemandAmps%

Total Downstream Demand Load (Amps)

%TotalDemandVA%

Total Downstream Demand Load (VA)

%TotalDesignAmps%

Total Downstream Design Load (Amps)

%TotalDesignVA%

Total Downstream Design Load (VA)

%Type%

Type, Specifications Tab (Bus Rating section)

%Unit%

U.S. or Metric

%Units%

kVA or Amps

%VAUnits%

Panel Load Units (VA or Amps), Description Tab

%Voltage%

Base Voltage (V)

%VoltageLL%

Line-to-line bus voltage

%Zone%

Line-to-line bus voltage

Grid

These variables display information that appears in the data grids in the schedule.

Variables

%BreakerAmps%

 

%BreakerCurrentRating%

Protective Device Trip (A), Description tab

%BreakerManufacturer%

Protective Device Manufacturer, Description tab

%BreakerStyle%

Protective Device Style, Description tab

%BreakerType%

Protective Device Type, Description tab

%CB_Fuse_Poles%

CB/Fuse Poles, Description tab

%CircuitkV%

 

%CodeFactor%

Code Factors, Description tab

%ConductorInsulation%

Conductor Insulation, Description tab

%ConductorNumberPerPhase%

Conductor Number Per Phase, Description tab

%ConductorSize%

Conductor Size, Description tab

%ConductorType%

Conductor Type, Description tab

%Description%

Load Description, Description tab (for MCC or panel)

%Library_Load%

Library Load, Description tab

%Load_Description%

 

%Load_Location%

Load Location, Description tab

%Load_Type%

 

%LoadCategory%

 

%LoadFacility%

 

%LoadFloor%

 

%LoadRef1%

 

%LoadRef1And2%

 

%LoadRef2%

 

%LocationName%

 

%LtPickupAmps%

 

%LtPickupSetting%

 

%Notes%

 

%Panel_Row_Comment%

 

%Phase%

 

%PhaseATotal%

Always reports the A phase.

Beginning with EasyPower 10.4, this variable is replaced with %Phase1Total% to support single-phase panel schedules.

%PhaseBTotal%

Always reports the B phase.

Beginning with EasyPower 10.4, this variable is replaced with %Phase2Total% to support single-phase panel schedules.

%PhaseCTotal%

Always reports the C phase.

Beginning with EasyPower 10.4, this variable is replaced with %Phase3Total% to support single-phase panel schedules.

%Phase1Total%

Reports the first phase (may be A, B, or C)

%Phase2Total%

Reports the second phase (may be A, B, C or blank)

%Phase3Total%

Reports the third phase (may be C or blank)

%SectionSpace%

Section Space, Description tab

%Poles%

Poles

%RefNumber%

 

%row%

Row Number, Description tab

%Tool%

 

%VA%

 

More Information