Switchgear Variables

See also Code Factor Variables.

General

These variables are available to all schedule templates.

Variables

%Current_Date_Time%

Format: "MM/DD/YYYY HH:MM:SS"

%EasyPower_Version%

EasyPower version

%FileName%

File name

%ProjectCode%

Project Code in File Properties

%ProjectName%

Project Name in File Properties

Abbreviation

These variables enable you to use abbreviations in your schedules. See Abbreviations in Schedule Load Types for more information.

Variables
%ShortName% Short Name
%TargetName% Long Name

Accessories

These variables display information from the table on the Accessories tab.

Variables

%AccessoryName%

Accessory name

%row%

Row number

%meterKVA%

Accessories tab

%meterLoadWithSafetyFactor%

Accessories tab

%meterMaxDemand%

Accessories tab

%meterNewDemandLoad%

Accessories tab

%meterNote%

Accessories tab

%meterPowerFactor%

Accessories tab

%meterReadingDate%

Accessories tab

%meterSafetyFactor%

Accessories tab

%meterTotalAmps%

Accessories tab

%meterTotalNewDemandLoad%

Accessories tab

Equipment

These variables display information from the various tabs in the equipment data dialog boxes.

Variables

%afh_boundary%

Estimated Arc Flash Boundary (inches), Summary tab, from the last fault and store

%afh_incident_energy%

Incident Energy (cal/cm2), Summary tab, from the last fault and store

%afh_ppe%

Arc Flash PPE, Summary tab, from the last fault and store

%afh_working_distance%

Arc Flash Working Distance (inches), from the last fault and store

%Area%

Area

%AverageCodeAmps%

Average Connected Amps Based on Total Demand Load

%AverageConnectedAmps%

Average Connected Amps Based on Total Connected Load

%BusRating%

Bus rating (A)

%CodeAmps%

Panel Summary tab

%Comment%

 

%ConnAmps%

Panel Summary tab

%Connected_Subfed_Total_Amps%

 

%Connected_Subfed_Total_VA%

Subfed Total VA

%ConnectedPhaseA_KVA%

 

%ConnectedPhaseB_KVA%

 

%ConnectedPhaseC_KVA%

 

%ConnectedTotal_KVA%

 

%DeviceCode%

Device Code

%DemandAmps%

Panel Summary tab

%DesignAmps%

Panel Summary tab

%DesignCapacity%

 

%DesignRating%

 

%IncomingFeederConductorRating%

 

%IncomingFeederTripAmps%

 

%IncomingFeederTripDevice%

 

%IndexValue%

 

%Manufacturer%

Manufacturer, Specifications tab (Bus Rating section)

%Material%

 

%Mounting%

Mounting, Specifications Tab

%Name%

Equipment ID Name

%RatingType%

 

%sc_sym_a%

Short Circuit Symmetrical A

%sc_sym_ka%

Short Circuit Symmetrical kA

%SCCR%

Bracing (kA), Specifications tab

%SwgUnits%

Specified Units (kVA or Amps), Switchboard/Switchgear/Panelboard tab

%SwitchType%

Bus Type (Type in Specifications tab), "Switchgear"

%TotalCodeAmps%

Total Downstream Code Factor Load (Amps), Switchboard/Switchgear/Panelboard tab

%TotalCodekVA%

 

%TotalCodeVA%

Total Downstream Code Factor Load (VA), Switchboard/Switchgear/Panelboard tab

%TotalConnAmps%

Total Downstream Connected Load (Amps), Switchboard/Switchgear/Panelboard tab

%TotalConnAverageAmps%

 

%TotalConnkVA%

 

%TotalConnVA%

Total Downstream Connected Load (VA), Switchboard/Switchgear/Panelboard tab

%TotalDemandAmps%

Total Downstream Demand Load (Amps), Switchboard/Switchgear/Panelboard tab

%TotalDemandkVA%

 

%TotalDemandVA%

Total Downstream Demand Load (VA), Switchboard/Switchgear/Panelboard tab

%TotalDesignAmps%

Total Downstream Design Load (Amps), Switchboard/Switchgear/Panelboard tab

%TotalDesignkVA%

 

%TotalDesignVA%

Total Downstream Design Load (VA), Switchboard/Switchgear/Panelboard tab

%Unit%

U.S. or Metric

%Units%

kVA or Amps

%UpstreamRating%

 

%VAUnits%

Panel Load Units (VA or Amps), Description Tab

%Voltage%

Base Voltage (V)

%Zone%

Zone

Grid

These variables display information that appears in the data grids in the schedule.

Variables

%BrkrMfg%

Breaker Manufacturer

%BrkrStyle%

Breaker Style

%CircuitNumber%

 

%CodeFactorsLoad%

 

%CodeFactorsLoadFLA%

 

%CodeFactorsLoadkVA%

 

%CodekVA%

 

%CodeVA%

Panel Summary tab

%ColumnNum%

 

%CondRating%

Conductor Rating (A), Switchboard/Switchgear/Panelboard tab

%ConnectedLoad%

 

%ConnectedLoadFLA%

 

%ConnectedLoadkVA%

 

%ConnkVA%

 

%ConnVA%

Panel Summary Tab

%Description%

Load Description, Description tab (for MCC or panel)

%DemandkVA%

 

%DemandLoad%

 

%DemandLoadFLA%

 

%DemandLoadkVA%

 

%DemandVA%

Panel Summary tab

%DesignkVA%

 

%DesignLoad%

 

%DesignLoadFLA%

 

%DesignLoadkVA%

 

%DesignVA%

Panel Summary tab

%DeviceRating%

Device Rating (A), Switchboard/Switchgear/Panelboard tab

%FeederID%

ID Name, Switchboard/Switchgear/Panelboard tab

%IntkA%

Protective Device Int kA, Description tab

%LoadFacility%

 

%LoadLocation%

 

%LoadFloor%

 

%LoadRef1%

 

%LoadRef1And2%

 

%LoadRef2%

 

%LtPickupAmps%

 

%LtPickupSetting%

 

%row%

Row Number, Description tab

%RowSpace%

 

%SectionSpace%

Section Space, Description tab

%TripAmps%

 

%TripMfg%

Trip Device Manufacturer

%TripPlug%

Trip Device Plug

%TripSensor%

Trip Device Sensor

%TripStyle%

Trip Device Style

%Type%

Device, Switchboard/Switchgear/Panelboard tab

More Information