Rectifier - Power Flow Tab
                                                
                                            
Figure 1: Rectifier Data – Power Flow tab
| Option | Description | 
|---|---|
| 
                                                         Thyristor Control  | 
                                                    
                                                         When the rectifier type is thyristor, the control can be one of the following: 
  | 
                                                
| 
                                                         Commutation Impedance  | 
                                                    
                                                         Commutation impedance is used to calculate the power flow using Kimbark’s equations. The rectifier must be fed by a dedicated transformer, where the characteristics are also defined here: 
  | 
                                                
| 
                                                         Input PF  | 
                                                    
                                                         When the rectifier type is IGBT, this specifies the control input power factor.  | 
                                                
| 
                                                         Efficiency  | 
                                                    
                                                         Ratio of output power to input power in percent.  | 
                                                
| 
                                                         Ctrl kV PU  | 
                                                    
                                                         For IGBT type or voltage control thyristor type, this is the controlled output voltage in per unit.  | 
                                                
| 
                                                         Current Set Point  | 
                                                    
                                                         The fixed value of output current in Amps for current controlled thyristor type.  | 
                                                
| 
                                                         Alpha Min  | 
                                                    
                                                         Minimum firing angle of the rectifier.  | 
                                                
| 
                                                         Alpha Max  | 
                                                    
                                                         Maximum firing angle of the rectifier.  | 
                                                