AFD - Connection Information
                                                 
                                            
Figure 1: Connection Information
| Option | Description | 
|---|---|
| ID Name | Uniquely identifies the equipment item. The program automatically assigns a name, but you can change it, if needed. The name can be up to 30 characters long. For adjustable frequency drives, the program automatically assigns the names AFD-1, AFD-2, AFD-3, and so on. | 
| Input Bus | ID name of the bus on the input side of AFD. The base kV of the bus is shown on the right. The base kV displays the highest voltage between the current carrying conductors. For 3-phase or line-to-line connected single-phase equipment, the base kV is the line-to-line (LL) voltage. For line-to-neutral (LN) connected single-phase equipment, the base kV is the line-to-neutral voltage. | 
| Output Bus | ID name of the bus on the output side of AFD. The base kV of the bus is shown on the right. The base kV displays the highest voltage between the current carrying conductors. For 3-phase or line-to-line connected single-phase equipment, the base kV is the line-to-line (LL) voltage. For line-to-neutral (LN) connected single-phase equipment, the base kV is the line-to-neutral voltage. | 
| Phase | The phase type for this item: 
 The phase applies to both the input and the output side of the AFD. | 
| 
                                                             (Information Icon) | The blue information icon indicates that the item must be disconnected to change the value. See Information Icon for more information. | 
 
                                                        