Code Factor Variables
Code factor variables are available to all schedule templates. There are two different styles you can use.
Code Factor Variables Styles 1
These code factor variables were primarily used in earlier EasyPower templates but also reflect updates made to the phasing column totals. These are still available but they do not show the breakdown by demand factor, which is available using the variables shown in the Code Factor Style 2 list.
%cfRow% |
Row number |
%cfName% |
Code factor name |
%cfPhase1% |
First phase (VA) |
%cfPhase2% |
Second phase (VA) |
%cfPhase3% |
Third phase (VA) |
%cfPhaseRowTotal% |
First phase + second phase + third phase |
%cfPhase1Total% |
Sum of %cfPhase1% for all rows table |
%cfPhase2Total% |
Sum of %cfPhase2% for all rows in table |
%cfPhase3Total% |
Sum of %cfPhase3% for all rows in table |
%cfPhaseTotal% |
Sum of %cfPhaseRowTotal% for all rows in table |
%PhaseATotalVA% |
A phase total |
%PhaseBTotalVA% |
B phase total |
%PhaseCTotalVA% |
C phase total |
%TotalPhaseVA% |
Sum of %cfPhaseRowTotal% for all rows in table |
Code Factor Variables Styles 2
These code factor variables display summary information from the code factor table and show code factor information at the demand factor level. They also can display connected sub-panel information including totals. These code factor variables provide a higher level of detail than those shown under Code Factor Styles 1.
%cfRow% |
Row number |
%cfName% |
Code factor name (for example, "Dwelling Units") |
%cfNameLevel1Only% |
Code factor name. This is blank if level 2 or 3 |
%cfHeader% |
A formatted combination of the code factor name and/or the VA range limits |
%cfLevelMin% |
The start of the VA range for this row |
%cfLevelMax% |
The end of the VA range for this row |
%cfFactor% |
Demand factor for this row (a percentage) |
%cfTotal% |
VA for this row, including connected and downstream |
%cfConnected% |
Connected VA for this row |
%cfDownStream% |
Downstream VA for this row |
%cfFactoredTotal% |
VA for this row, with the demand factor applied |
%cfFactoredConnected% |
Connected VA for this row, with demand factor applied |
%cfFactoredDownStream% |
Downstream VA for this row, with demand factor applied |
%cfTotalSum% |
Sum of %cfTotal% for all rows |
%cfConnectedSum% |
Sum of %cfConnected% for all rows |
%cfDownStreamSum% |
Sum of %cfDownStream% for all rows |
%cfFactoredTotalSum% |
Sum of %cfFactoredTotal% for all rows |
%cfFactoredConnectedSum% |
Sum of %cfFactoredConnected% for all rows |
%cfFactoredDownStreamSum% |
Sum of %cfFactoredDownStream% for all rows |
%cfQuantity% |
The total quantity of loads for the code factor. |