Rectifier - Power Flow Tab
Figure 1: Rectifier Data – Power Flow tab
| Option | Description |
|---|---|
|
Thyristor Control |
When the rectifier type is thyristor, the control can be one of the following:
|
|
Commutation Impedance |
Commutation impedance is used to calculate the power flow using Kimbark’s equations. The rectifier must be fed by a dedicated transformer, where the characteristics are also defined here:
|
|
Input PF |
When the rectifier type is IGBT, this specifies the control input power factor. |
|
Efficiency |
Ratio of output power to input power in percent. |
|
Ctrl kV PU |
For IGBT type or voltage control thyristor type, this is the controlled output voltage in per unit. |
|
Current Set Point |
The fixed value of output current in Amps for current controlled thyristor type. |
|
Alpha Min |
Minimum firing angle of the rectifier. |
|
Alpha Max |
Maximum firing angle of the rectifier. |
More Information
- Notes on Rectifier Power Flow Modeling
- Rectifier Data
- Database Dialog Box Toolbar
- Rectifier - Connection Information
- Rectifier - Specifications Tab
- Rectifier - Power Flow Tab
- Rectifier - Harmonics Tab
- Rectifier - Reliability Tab
- Rectifier - Location Tab
- Rectifier - Comments Tab
- Rectifier - Hyperlinks Tab
- Rectifier - Collected Data Tab
- Rectifier - Media Gallery Tab