Sentinel Admin Control Center Configuration

If your computer is unable to detect an SL key installed on a remote computer on your network, you may need to update configurations in the Sentinel Admin Control Center on the remote computer to explicitly specify the server.

To start the Sentinel Admin Control Center and update the configurations:

  1. In your browser, navigate to http://localhost:1947.
  2. In the Options section on the left, click Configuration.

Figure 1: Options Menu

  1. On the Configuration page, click the Access to Remote License Managers tab.

Figure 2: Configuration Page

  1. In the Specify Search Parameters box, enter either the computer name or the IP address of the remote SL key server, and then click Submit.

Note: It can take a couple of minutes for this setting to take effect. To verify that you are able to detect the key, click the Sentinel Keys link in the Options section to view the list of keys. After a brief period, your key should appear in this list.

More Information

Key Management Utility  
Online Transfer  
     

www.easypower.com

EasyPower, LLC

7730 SW Mohawk St.

Tualatin, OR 97062

(503)655-5059

techsupport@easypower.com

feedback@easypower.com

EasyPower knowledge base

EasyPower Version 9.8

Copyright © 2017 EasyPower, LLC. All Rights Reserved.

Help was last updated on 7/10/2017