MCC Variables

Global Variables
%Code_Factors_FLA% MCC Code Factors Load FLA (Including Downstream Load), Summary tab
%Code_Factors_kVA% MCC Code Factors Load kVA (Including Downstream Load), Summary tab
%Connected_FLA% Connected MCC Load FLA, Summary tab
%Connected_HP% Connected MCC Load Motor HP, Summary tab
%Connected_kVA% Connected MCC Load kVA, Summary tab
%Demand_FLA% Demand MCC Load FLA, Summary tab
%Demand_kVA% Demand MCC Load kVA, Summary tab
%Aic% SC Rating (kA), Specifications Tab (Bus Rating section)
%Amps% Horz Bus Rating (A), Specifications Tab
%Location% Location, Specifications Tab
%Main% Main Incoming Device Amps (A), MCC/Panel Incoming Tab
%Service% Service, MCC/Panel Specifications Tab
%EasyPower_Version% EasyPower Version
%FileName% File Name
%Name% Equipment ID Name
%ProjectName% Project Name, located in File Properties
%Voltage% Base Voltage (V)
%Mounting%

Mounting

%Panel_Description% Panel Description
%ProjectCode% Project Code
%Connected_Subfed_Total_VA% Subfed Total VA
%AverageConnectedAmps% Average Connected Amps Based on Total Connected Load
%AverageCodeAmps%   Average Connected Amps Based on Total Demand Load

 

Short Circuit (stored on fault)
%sc_sym_a% Short Circuit Sym A
%mcc_sym_ka% Lowest Rated Equipment kA, Description tab

 

Arc Flash
%afh_incident_energy% Incident Energy (cal/cm2), Summary tab
%afh_boundary% Estimated Arc Flash Boundary (inches), Summary tab
%afh_working_distance% Arc Flash Working Distance (inches)
%afh_ppe% Arc Flash PPE, Summary tab

 

Grid
%CondNoPh% Conductor No/Ph, Description tab
%CondSize% Conductor Size, Description tab
%CondType% Conductor Type, Description tab
%EquipmentName% Equipment Name, Description tab
%HPkW% Motor HP (rounded to nearest whole number), Description tab
%IntkA% Protective Device Int kA, Description tab
%MotorkV% Motor kV, MCC Description tab
%NEMACode% Motor NEMA Code, MCC Description tab
%StatickV% Static Load kV, MCC Description tab
%StatickVAR% Static Load kVAR, MCC Description tab
%StatickW% Static Load kW, MCC Description tab
%TripA% Protective Device Trip Amps, Description tab
%SectionSpace% Section Space, Description tab
%Description% Load Description, Description tab

 

Accessories Tab
%AccessoryName% Accessory Name
%meterKVA% Meter KVA
%meterMaxDemand% Maximum Demand
%meterReadingDate% Reading Date
%meterNote% Metering Note
%meterSafetyFactor% Safety Factor
%meterLoadWithSafetyFactor% Meter Load with Safety Factor
%meterNewDemandLoad% Added New Demand Load
%meterTotalNewDemandLoad% Total New Demand Load
%meterTotalAmps% Total Amps
%meterPowerFactor% Power Factor

 

Code Factors (by Demand Factor)
%cfLevel1Header% Code Factor Name
%cfConnectedLevel1% Connected Load up to Demand Factor 1
%cfDownStreamLevel1% Downstream Load up to Demand Factor 1
%cfTotalLevel1% Total Load up to Demand Factor 1
%cfCodeFactor1% Code Factor of Demand Factor 1
%cfFactoredTotalLevel1% Total Code Factor of Demand Factor 1
 
%cfLevel2Header% Code Factor Name
%cfConnectedLevel2% Connected Load up to Demand Factor 2
%cfDownStreamLevel2% Downstream Load up to Demand Factor 2
%cfTotalLevel2% Total Load up to Demand Factor 2
%cfCodeFactor2% Code Factor of Demand Factor 2
%cfFactoredTotalLevel2% Total Code Factor of Demand Factor 2
 
%cfLevel3Header% Code Factor Name
%cfConnectedLevel3% Connected Load up to Demand Factor 3
%cfDownStreamLevel3% Downstream Load up to Demand Factor 3
%cfTotalLevel3% Total Load up to Demand Factor 3
%cfCodeFactor3% Code Factor of Demand Factor 3
%cfFactoredTotalLevel3% Total Code Factor of Demand Factor 3

 

More Information