Global Variables See also Panel Summary Tab Variables for more information about the global variables. |
|
%Code_Factor_I% | Panel Summary Tab. |
%Code_Factor_VA% | Panel Summary Tab. |
%Code_Factor_VA% | Panel Summary Tab. |
%CodeAmps% | Panel Summary Tab. |
%CodeVA% | Panel Summary Tab. |
%ConnAmps% | Panel Summary Tab. |
%Connected_A_I% | Panel Summary Tab. |
%Connected_A_PF% | Panel Summary Tab. |
%Connected_A_VA% | Panel Summary Tab. |
%Connected_A_Vars% | Panel Summary Tab. |
%Connected_A_Watts% | Panel Summary Tab. |
%Connected_B_I% | Panel Summary Tab. |
%Connected_B_PF% | Panel Summary Tab. |
%Connected_B_VA% | Panel Summary Tab. |
%Connected_B_Vars% | Panel Summary Tab. |
%Connected_B_Watts% | Panel Summary Tab. |
%Connected_C_I% | Panel Summary Tab. |
%Connected_C_PF% | Panel Summary Tab. |
%Connected_C_VA% | Panel Summary Tab. |
%Connected_C_Vars% | Panel Summary Tab. |
%Connected_C_Watts% | Panel Summary Tab. |
%Connected_Total_I% | Panel Summary Tab. |
%Connected_Total_PF% | Panel Summary Tab. |
%Connected_Total_VA% | Panel Summary Tab. |
%Connected_Total_Vars% | Panel Summary Tab. |
%Connected_Total_Watts% | Panel Summary Tab. |
%ConnVA% | Panel Summary Tab. |
%Current_Date_Time% | Current Date/Time, Format: "MM/DD/YYYY HH:MM:SS" |
%Demand_A_I% | Panel Summary Tab. |
%Demand_A_PF% | Panel Summary Tab. |
%Demand_A_VA% | Panel Summary Tab. |
%Demand_A_Vars% | Panel Summary Tab. |
%Demand_A_Watts% | Panel Summary Tab. |
%Demand_B_I% | Panel Summary Tab. |
%Demand_B_PF% | Panel Summary Tab. |
%Demand_B_VA% | Panel Summary Tab. |
%Demand_B_Vars% | Panel Summary Tab. |
%Demand_B_Watts% | Panel Summary Tab. |
%Demand_C_I% | Panel Summary Tab. |
%Demand_C_PF% | Panel Summary Tab. |
%Demand_C_VA% | Panel Summary Tab. |
%Demand_C_Vars% | Panel Summary Tab. |
%Demand_C_Watts% | Panel Summary Tab. |
%Demand_Total_I% | Panel Summary Tab. |
%Demand_Total_PF% | Panel Summary Tab. |
%Demand_Total_VA% | Panel Summary Tab. |
%Demand_Total_Vars% | Panel Summary Tab. |
%Demand_Total_Watts% | Panel Summary Tab. |
%DemandAmps% | Panel Summary Tab. |
%DemandVA% | Panel Summary Tab. |
%Design_I% | Panel Summary Tab. |
%Design_VA% | Panel Summary Tab. |
%DesignAmps% | Panel Summary Tab. |
%DesignVA% | Panel Summary Tab. |
%Enclosure% | "Enclosure" Field, Specifications Tab |
%Fed_By% | "Fed By" Field, Specifications Tab |
%Header_Comment% | "Header Comment" Field, Specifications Tab |
%Manufacturer% | "Manufacturer" Field, Specifications Tab (Bus Rating section) |
%Mounting% | "Mounting" Field, Specifications Tab |
%Panel_Description% | "Description" Field, Specifications Tab |
%Panel_Rating_kA% | Lowest Rated Equipment kA (in Description tab) |
%Type% | "Type" Field, Specifications Tab (Bus Rating section) |
%VAUnits% | Panel Load Units ("VA" or "Amps"), Description Tab |
%TotalCodeAmps% | Panel Summary Tab. |
%TotalCodeVA% | Panel Summary Tab. |
%TotalConnAmps% | Panel Summary Tab. |
%TotalConnVA% | Panel Summary Tab. |
%TotalDemandAmps% | Panel Summary Tab. |
%TotalDemandVA% | Panel Summary Tab. |
%TotalDesignAmps% | Panel Summary Tab. |
%TotalDesignVA% | Panel Summary Tab. |
%Aic% | SC Rating (kA), MCC/Panel Specifications Tab (Bus Rating section) |
%Amps% | "Main Bus Rating (A)" Field, Specifications Tab |
%Location% | "Location" Field, Specifications Tab |
%Main% | Main Incoming Device Amps (A), Incoming Tab |
%Service% | "Service" Field, Specifications Tab |
%EasyPower_Version% | EasyPower Version |
%FileName% | File Name |
%Name% | Equipment ID Name |
%ProjectName% | Project Name, located in File Properties |
%Voltage% | Base Voltage (V) |
%Type% | "Type" Field, Specifications Tab |
%Poles% | Poles |
%Connected_Subfed_Total_VA% | Subfed Total VA |
%AverageConnectedAmps% | Average Connected Amps Based on Total Connected Load |
%AverageCodeAmps% | Average Connected Amps Based on Total Demand Load |
Short Circuit (stored on fault) | |
%sc_sym_ka% | Short Circuit Sym kA |
%sc_sym_a% | Short Circuit Sym A |
Arc Flash (stored on fault) | |
%afh_incident_energy% | Incident Energy (cal/cm2), Summary tab |
%afh_boundary% | Estimated Arc Flash Boundary (inches), Summary tab |
%afh_working_distance% | Arc Flash Working Distance (inches) |
%afh_ppe% | Arc Flash PPE, Summary tab |
Grid | |
%CB_Fuse_Poles% | "CB/Fuse Poles" column, Description tab |
%CodeFactor% | "Code Factors" column, Description tab |
%Library_Load% | "Library Load" column, Description tab |
%Load_Location% | "Load Location" column, Description tab |
%PhaseATotal% | Phase A Total, Description tab (set View: "Detailed - Both Sides") -- invalidated when inapplicable |
%PhaseBTotal% | Phase B Total, Description tab (set View: "Detailed - Both Sides") -- invalidated when inapplicable |
%PhaseCTotal% | Phase C Total, Description tab (set View: "Detailed - Both Sides") -- invalidated when inapplicable |
%row% | Row Number, Description tab |
%VA% | Connected Load VA (A, B, or C -- depending on row #), Description tab |
%BreakerCurrentRating% | Protective Device Trip (A), Description tab |
%BreakerManufacturer% | Protective Device Manufacturer, Description tab |
%BreakerStyle% | Protective Device Style, Description tab |
%BreakerType% | Protective Device Type, Description tab |
%ConductorInsulation% | Conductor Insulation, "Cond Insul" column, Description tab |
%ConductorNumberPerPhase% |
Conductor Number Per Phase, "Cond No./Ph" column, Description tab |
%ConductorType% | Conductor Type, "Cond Type" column, Description tab |
%ConductorSize% | Conductor Size, "Cond Size" column, Description tab |
%Description% | "Load Description" column, Description tab |
Accessories Tab | |
%AccessoryName% | Accessory Name |
%meterKVA% | Meter KVA |
%meterMaxDemand% | Maximum Demand |
%meterReadingDate% | Reading Date |
%meterNote% | Metering Note |
%meterSafetyFactor% | Safety Factor |
%meterLoadWithSafetyFactor% | Meter Load with Safety Factor |
%meterNewDemandLoad% | Added New Demand Load |
%meterTotalNewDemandLoad% | Total New Demand Load |
%meterTotalAmps% | Total Amps |
%meterPowerFactor% | Power Factor |
Code Factors | |
%cfRow% | Code Factor Row Number |
%cfName% | Code Factor Name |
%cfPhase1% | Aph (VA) |
%cfPhase2% | Bph (VA) |
%cfPhase3% | Cph (VA) |
%cfPhaseRowTotal% | Phase Row Total (VA), Aph + Bph + Cph |
%cfPhaseTotal% | Calculated Phase Total |
Code Factors (by Demand Factor) | |
%cfLevel1Header% | Code Factor Name |
%cfConnectedLevel1% | Connected Load up to Demand Factor 1 |
%cfDownStreamLevel1% | Downstream Load up to Demand Factor 1 |
%cfTotalLevel1% | Total Load up to Demand Factor 1 |
%cfCodeFactor1% | Code Factor of Demand Factor 1 |
%cfFactoredTotalLevel1% | Total Code Factor of Demand Factor 1 |
%cfLevel2Header% | Code Factor Name |
%cfConnectedLevel2% | Connected Load up to Demand Factor 2 |
%cfDownStreamLevel2% | Downstream Load up to Demand Factor 2 |
%cfTotalLevel2% | Total Load up to Demand Factor 2 |
%cfCodeFactor2% | Code Factor of Demand Factor 2 |
%cfFactoredTotalLevel2% | Total Code Factor of Demand Factor 2 |
%cfLevel3Header% | Code Factor Name |
%cfConnectedLevel3% | Connected Load up to Demand Factor 3 |
%cfDownStreamLevel3% | Downstream Load up to Demand Factor 3 |
%cfTotalLevel3% | Total Load up to Demand Factor 3 |
%cfCodeFactor3% | Code Factor of Demand Factor 3 |
%cfFactoredTotalLevel3% | Total Code Factor of Demand Factor 3 |
Schedule Variables | |
Schedules | |
Panel Summary Tab Variables |
![]() |