EasyPower 10.0 Release Notes

For information on the latest service packs for this release, see 10.0 SP2 Release Notes and 10.0 SP1 Release Notes.

The following features are included in the 10.0 release:

IEC-60909 in Short Circuit and Coordination

Watch the Video 

EasyPower’s short circuit calculations now include expanded support for the IEC-60909 standard. There are new system options for IEC, new and improved IEC calculations, and new terminology that reflects the IEC standard. Equipment dialog boxes and reports have been modified to include new IEC fields. Support for IEC symbols has been enhanced using the new Custom Symbols feature described below. The Equipment Palette, Insert tab, one-line diagrams, and right-click context menu now display IEC symbols when the IEC symbol option is selected. Metric options have been expanded. See Short Circuit Reference (IEC) for more information on IEC short circuit analysis.

EasyPower’s Coordination focus now supports integration with IEC Short Circuit. TCC plots and remote voltage and current calculations are now available. See Tutorial - Protective Device Coordination (IEC) for more information.

Figure 1: IEC Short Circuit Options

Figure 2: IEC Short Circuit Reports

Figure 3: IEC Options in Short Circuit

Figure 4: IEC Options in Relay Data

Custom One-line Text and Equipment Data

Watch the Video 

You now have much more control over the text that appears next to the equipment symbols on your one-lines. You can choose what equipment properties and text to use and the order in which it appears. Several options for text visibility are now controlled using the custom text feature. See Customizing the One-line Text for more information.

Figure 5: One-line Text Tab

Custom One-line Symbols

Watch the Video 

New templates have been added that enable you to manually adjust your equipment symbols using XML. You can use File Locations to control which templates are used for new one-lines. See Customizing One-line Symbols for more information.

Figure 6: One-line Symbols Tab

OnSite Enhancements

We have made improvements to the process for importing OnSite files into EasyPower one-lines, including an improved one-line layout and better equipment matching.

2018 NFPA 70E

We have made updates to arc flash approach boundaries, PPE levels, labels, and have added the ability to display incident energy in joules/cm2. The device library has been updated to reference the new 70E tables.

Chinese EasyPower Version

EasyPower is now available in a translated version for Chinese. Both the user interface and the product documentation have been translated. This effort paves the way for future language translations. Contact sales@easypower.com for more information.

Figure 7: Chinese EasyPower

And much more!

For more details on the release and bug fix information, see EasyPower 10.0 Release Details.

Note: New release features often include changes to the database. This may affect what you see in the Database Browser and also what is included when you export data into CSV files. If your existing work processes rely on information from the database, be sure to review your processes after you update your software.

More Information

Release Notes Archive EasyPower 10.0 Release Details
10.0 SP1 Release Notes 10.0 SP2 Release Notes