Layout Tab

The layout options affect the way your one-line model is displayed when you use the Auto Layout feature. There are separate options for vertical and horizontal equipment spacing. The numbers indicate the spacing in grid points. A graphic diagram illustrates the spacing you are defining.

Note: The graphic diagram is for illustrative purposes only, and does not adjust when the spacing is changed.

The initial values for Grid Spaces are derived from the layout options file selected in File Locations. There, you can choose from default, compact, or extended layouts. See File Locations Tab for more information.

You can also change the numbers here. If you change the number here, it updates the selected layout options file with your custom values.

These layout options are also used as the initial spacing values when you manually place items on the one-line.

The Layout tab of the Options dialog box is shown.

Figure 1: Layout tab of the Options Dialog Box

Option Descriptions
Option Description

Diagram

Vertical Equipment Spacing (in grid spaces)

From Bus / To Bus

The vertical distance from one a bus to a bus.

A yellow highlight illustrates the spacing between two buses.

From Bus / To Load

The vertical distance from a bus to a load.

A yellow highlight illustrates the spacing between a bus and a load.

From Bus / To Protective Device

The vertical distance from a bus to a protective device.

A yellow highlight illustrates the spacing between a bus and a protective device.

From Source / To Bus

The vertical distance from a power source to a bus.

A yellow highlight illustrates the spacing between a power source and a bus.

From Protective Device / To Bus

The vertical distance from a protective device to a bus.

A yellow highlight illustrates the spacing between a protective device and a bus.

Horizontal Equipment Spacing (in grid spaces)

Adjacent Unconnected Buses

The horizontal spacing between two adjacent unconnected buses.

A yellow highlight illustrates the spacing between two adjacent buses.

Branch to Bus Edge

The horizontal spacing between the branch to the edge of a bus.

A yellow highlight illustrates the spacing between the branch to the edge of a bus.

Branch to Branch

The horizontal spacing between two branches.

A yellow highlight illustrates the spacing between two branches.

Relay Spacing

The horizontal spacing between two relays.

A yellow highlight illustrates the spacing between two relays.

Additional Options

Preserve node buses during layout This option enables you to choose whether to keep existing bus nodes as nodes (with a bus width of zero), or to allow these nodes to be resized automatically during auto layout.

 

Preserve existing branch order on buses (can reduce layout quality) This option enables you to choose whether to preserve the order of branches on buses which can reduce layout quality, or instead to disregard the order of branches on buses and let the layout calculations determine the optimal placement.

 