You are here: Using EasyPower With Other Programs > Importing an SKM Format File

Importing an SKM Format File

SKM programs include the ability to create an export of equipment data into a CSV file. If you have a data in this CSV format, you can import the file into EasyPower. After the import is complete, a report is available that indicates the success of the import with information about any errors found.

For information about creating an export file in SKM, see Creating an SKM Data Export CSV File.

Note: Internet access is required for the import to complete successfully. The process uses a mapping file stored on the web to match the equipment data.

Importing the File

To import the file, do the following:

  1. Copy the exported file to the computer on which you want to perform the import.
  2. Click the EasyPower button and select Import > Import SKM Data.
  3. Figure 1: Import CSV Data Dialog Box

  4. Click Browse to locate the import file, select the file, and then click Open.
  5. Under Destination, select whether you want the data imported into a new one-line or the current one-line.
  6. Note: If you import the .CSV file more than once into the same one-line, the new import overwrites the existing data.

  7. Select whether you want the import to contain US or metric units.
  8. Click Import.
  9. After the import is complete, an Import Results dialog box is displayed. You can review the import information here. Click Save Text to save a copy of the results in a text file in a location you specify.
  10. Figure 2: Import Results

  11. Click Close to close the results dialog box. The Import Error/Warning log is displayed.
  12. Figure 3: Import Error/Warning Log

  13. Click Edit to open the equipment data dialog box for the item to enter any missing information. Messages in the log can help you determine which changes to make.
  14. Click Clear to remove an item from the import log.
  15. When you close the Import Error/Warning log, the one-line is displayed.
  16. Figure 4: One-line Diagram after Import

If you find that items are missing from the import, ensure that the import file contains the items. You may need to modify your custom format in SKM to import the missing items. See Creating a Custom Format for more information.

Tip: You can view the items in the Database Browser to look for import inconsistencies. See Database Browser and Report for more information.

Viewing the Import Log

You can view the contents of the import log at any time by clicking the EasyPower button and selecting Import > View Import Log.

Note: When you create equipment items from an import file, a new Imported Data tab appears in the item's data dialog. The import information is stored there for your reference.

More Information

Using EasyPower with Other Programs  
Creating an SKM Data Export CSV File  