Tool Point of Connection - Connection Information
Figure 1: Connection Information
Option | Description |
---|---|
Tool ID |
The identifier for the tool. You can select from the list, or click Tools to create a new tool. See Edit Tools for more information. |
Tool Type |
This represents a type of tool. |
Facility |
The facility where the tool point of connection exists. This information comes from the tool. See Edit Tools for more information. Facilities are set up under Tools > Facilities > Facilities. |
Func. Area |
The functional area where the tool point of connection exists. This information comes from the tool. See Edit Tools for more information. |
Bay |
The bay where the tool point of connection exists. This information comes from the tool. See Edit Tools for more information. |
Ref# |
The reference number for the point of connection. This information appears on the one-line. |
Base kV |
Base kV for the tool point of connection. Note that the tool point of connection must have a kV entered before equipment can be connected to it. Anything less than 1 kV is considered low voltage, anything 1 kV or more is high voltage. The base kV displays the highest voltage between the current carrying conductors. For 3-phase or line-to-line connected single-phase equipment, the base kV is the line-to-line (LL) voltage. For line-to-neutral (LN) connected single-phase equipment, the base kV is the line-to-neutral voltage. The list of base kV values comes from the table in Tools > Options > System. You can choose from the list or manually type in a value. The base kV is limited to 1 kV or less. |
Phase |
The phase type for this item:
|
Service |
The service for this item.
|
Lock Auto-Sizing |
When this check box is selected, the tool point of connection cannot be auto-sized. |
(Information Icon) |
The blue information icon indicates that the item must be disconnected to change the value. See Information Icon for more information. |
More Information
- Edit Tools
- Tool Point of Connection Data
- Database Dialog Box Toolbar
- Tool Point of Connection - Specifications Tab
- Tool Point of Connection - Description Tab
- Tool Point of Connection - Harmonics Tab
- Tool Point of Connection - Arc Flash Hazard Tab
- Tool Point of Connection - Accessories Tab
- Tool Point of Connection - Reliability Tab
- Tool Point of Connection - Location Tab
- Tool Point of Connection - Comments Tab
- Tool Point of Connection - Hyperlinks Tab
- Tool Point of Connection - Collected Data Tab
- Tool Point of Connection - Media Gallery Tab