MCC Variables
See also Code Factor Variables.
General
These variables are available to all schedule templates.
%Current_Date_Time% |
Format: "MM/DD/YYYY HH:MM:SS" |
%EasyPower_Version% |
EasyPower version |
%FileName% |
File name |
%ProjectCode% |
Project Code in File Properties |
%ProjectName% |
Project Name in File Properties |
Abbreviations
These variables enable you to use abbreviations in your schedules. See Abbreviations in Schedule Load Types for more information.
%ShortName% | Short Name |
%TargetName% | Long Name |
Accessories
These variables display information from the table on the Accessories tab.
%AccessoryName% |
Accessory name |
%row% |
Row number |
%meterKVA% |
Accessories tab |
%meterLoadWithSafetyFactor% |
Accessories tab |
%meterMaxDemand% |
Accessories tab |
%meterNewDemandLoad% |
Accessories tab |
%meterNote% |
Accessories tab |
%meterPowerFactor% |
Accessories tab |
%meterReadingDate% |
Accessories tab |
%meterSafetyFactor% |
Accessories tab |
%meterTotalAmps% |
Accessories tab |
%meterTotalNewDemandLoad% |
Accessories tab |
Equipment
These variables display information from the various tabs in the equipment data dialog boxes.
%AccessoryName% |
Accessory Name, Accessories tab |
%afh_boundary% |
Estimated Arc Flash Boundary (inches), Summary tab, from the last fault and store |
%afh_incident_energy% |
Incident Energy (cal/cm2), Summary tab, from the last fault and store |
%afh_ppe% |
Arc Flash PPE, Summary tab, from the last fault and store |
%afh_working_distance% |
Arc Flash Working Distance (inches), from the last fault and store |
%Aic% |
SC Rating (kA), Specifications Tab (Bus Rating section) |
%Amps% |
Panel - main bus rating (A); MCC - horizontal bus rating (A) |
%Area% |
Area |
%AverageCodeAmps% |
Average Connected Amps Based on Total Demand Load |
%AverageConnectedAmps% |
Average Connected Amps Based on Total Connected Load |
%BusRating% |
Bus rating (A) |
%Code_Factors_FLA% |
MCC Code Factors Load FLA (Including Downstream Load), Summary tab |
%Code_Factors_kVA% |
MCC Code Factors Load kVA (Including Downstream Load), Summary tab |
%Comment% |
Comments tab |
%Connected_FLA% |
Connected MCC Load FLA, Summary tab |
%Connected_HP% |
Connected MCC Load Motor HP, Summary tab |
%Connected_kVA% |
Connected MCC Load kVA, Summary tab |
%Connected_Subfed_Total_Amps% |
Subfed Total Amps |
%Connected_Subfed_Total_VA% |
Subfed Total VA |
%ConnectedPhaseA_KVA% |
|
%ConnectedPhaseB_KVA% |
|
%ConnectedPhaseC_KVA% |
|
%ConnectedTotal_KVA% |
|
%DeviceCode% |
Device Code |
%Demand_FLA% |
Demand MCC Load FLA, Summary tab |
%Demand_kVA% |
Demand MCC Load kVA, Summary tab |
%Fed_By% |
Fed By, Specifications Tab |
%Header_Comment% |
Header Comment, Specifications Tab |
%IncomingFeederConductorRating% |
|
%IncomingFeederTripAmps% |
|
%IncomingFeederTripDevice% |
|
%IncomingFrameLTPU% |
|
%IncomingFramePlug% |
|
%IncomingMfr% |
|
%IncomingPlugLTPU% |
|
%IncomingRating% |
|
%IncomingStyle% |
|
%Location% |
Location, Specifications Tab |
%Main% |
Main Incoming Device Type, Incoming Tab |
%MainDeviceTripAmps% |
Main Incoming Device Trip Amps (A) - based on LTPU |
%Manufacturer% |
Manufacturer, Specifications Tab (Bus Rating section) |
%Material% |
Specifications tab |
%mcc_sc_ka% |
Lowest Rated Equipment kA, Description tab |
%Mounting% |
Mounting, Specifications Tab |
%Name% |
Equipment ID Name |
%Panel_Description% |
Panel Description |
%RatingType% |
|
%sc_sym_a% |
Short Circuit Symmetrical A |
%sc_sym_ka% |
Short Circuit Symmetrical kA |
%SCCR% |
Bracing (kA), Specifications Tab |
%Service% |
Service, MCC/Panel Specifications tab |
%SwgUnits% |
Specified Units (kVA or Amps) |
%SwitchType% |
Bus Type (Type in Specifications tab) |
%TotalCodeAmps% |
Total Downstream Code Factor Load (Amps) |
%TotalCodeVA% |
Total Downstream Code Factor Load (VA) |
%TotalConnAmps% |
Total Downstream Connected Load (Amps) |
%TotalConnAverageAmps% |
|
%TotalConnkVA% |
|
%TotalConnVA% |
Total Downstream Connected Load (VA) |
%TotalDemandAmps% |
Total Downstream Demand Load (Amps) |
%TotalDemandVA% |
Total Downstream Demand Load (VA) |
%TotalDesignAmps% |
Total Downstream Design Load (Amps) |
%TotalDesignVA% |
Total Downstream Design Load (VA) |
%Unit% |
U.S. or Metric |
%Units% |
kVA or Amps |
%VertBusRating% | |
%VoltageLL% |
Base kV |
%Voltage% |
Base Voltage (V) |
%Zone% |
Zone |
Grid
These variables display information that appears in the data grids in the schedule.
%BreakerCurrentRating% |
Protective Device Trip (A), Description tab |
%BreakerManufacturer% |
Protective Device Manufacturer, Description tab |
%BreakerStyle% |
Protective Device Style, Description tab |
%BreakerType% |
Protective Device Type, Description tab |
%CondNoPh% |
Conductor No/Ph, Description tab |
%CondSize% |
Conductor Size, Description tab |
%CondType% |
Conductor Type, Description tab |
%ConductorInsulation% |
Conductor Insulation, Description tab |
%ConductorNumberPerPhase% |
Conductor Number Per Phase, Description tab |
%ConductorSize% |
Conductor Size, Description tab |
%ConductorType% |
Conductor Type, Description tab |
%Description% |
Load Description, Description tab (for an MCC or panel) |
%EquipmentName% |
Equipment Name, Description tab |
%HPkW% |
Motor HP (rounded to nearest whole number), Description tab |
%IntkA% |
Protective Device Int kA, Description tab |
%Load_Description% |
|
%LtPickupAmps% |
|
%LtPickupSetting% |
|
%MotorkV% |
Motor kV, MCC Description tab |
%NEMACode% |
Motor NEMA Code, MCC Description tab |
%row% |
Row Number, Description tab |
%SectionSpace% |
Section Space, Description tab |
%StatickV% |
Static Load kV, MCC Description tab |
%StatickVAR% |
Static Load kVAR, MCC Description tab |
%StatickW% |
Static Load kW, MCC Description tab |
%TripA% |
Protective Device Trip Amps, Description tab |