Switchgear Variables
See also Code Factor Variables.
General
These variables are available to all schedule templates.
%Current_Date_Time% |
Format: "MM/DD/YYYY HH:MM:SS" |
%EasyPower_Version% |
EasyPower version |
%FileName% |
File name |
%ProjectCode% |
Project Code in File Properties |
%ProjectName% |
Project Name in File Properties |
Abbreviation
These variables enable you to use abbreviations in your schedules. See Abbreviations in Schedule Load Types for more information.
%ShortName% | Short Name |
%TargetName% | Long Name |
Accessories
These variables display information from the table on the Accessories tab.
%AccessoryName% |
Accessory name |
%row% |
Row number |
%meterKVA% |
Accessories tab |
%meterLoadWithSafetyFactor% |
Accessories tab |
%meterMaxDemand% |
Accessories tab |
%meterNewDemandLoad% |
Accessories tab |
%meterNote% |
Accessories tab |
%meterPowerFactor% |
Accessories tab |
%meterReadingDate% |
Accessories tab |
%meterSafetyFactor% |
Accessories tab |
%meterTotalAmps% |
Accessories tab |
%meterTotalNewDemandLoad% |
Accessories tab |
Equipment
These variables display information from the various tabs in the equipment data dialog boxes.
%afh_boundary% |
Estimated Arc Flash Boundary (inches), Summary tab, from the last fault and store |
%afh_incident_energy% |
Incident Energy (cal/cm2), Summary tab, from the last fault and store |
%afh_ppe% |
Arc Flash PPE, Summary tab, from the last fault and store |
%afh_working_distance% |
Arc Flash Working Distance (inches), from the last fault and store |
%Area% |
Area |
%AverageCodeAmps% |
Average Connected Amps Based on Total Demand Load |
%AverageConnectedAmps% |
Average Connected Amps Based on Total Connected Load |
%BusRating% |
Bus rating (A) |
%CodeAmps% |
Panel Summary tab |
%Comment% |
|
%ConnAmps% |
Panel Summary tab |
%Connected_Subfed_Total_Amps% |
|
%Connected_Subfed_Total_VA% |
Subfed Total VA |
%ConnectedPhaseA_KVA% |
|
%ConnectedPhaseB_KVA% |
|
%ConnectedPhaseC_KVA% |
|
%ConnectedTotal_KVA% |
|
%DeviceCode% |
Device Code |
%DemandAmps% |
Panel Summary tab |
%DesignAmps% |
Panel Summary tab |
%DesignCapacity% |
|
%DesignRating% |
|
%IncomingFeederConductorRating% |
|
%IncomingFeederTripAmps% |
|
%IncomingFeederTripDevice% |
|
%IndexValue% |
|
%Manufacturer% |
Manufacturer, Specifications tab (Bus Rating section) |
%Material% |
|
%Mounting% |
Mounting, Specifications Tab |
%Name% |
Equipment ID Name |
%RatingType% |
|
%sc_sym_a% |
Short Circuit Symmetrical A |
%sc_sym_ka% |
Short Circuit Symmetrical kA |
%SCCR% |
Bracing (kA), Specifications tab |
%SwgUnits% |
Specified Units (kVA or Amps), Switchboard/Switchgear/Panelboard tab |
%SwitchType% |
Bus Type (Type in Specifications tab), "Switchgear" |
%TotalCodeAmps% |
Total Downstream Code Factor Load (Amps), Switchboard/Switchgear/Panelboard tab |
%TotalCodekVA% |
|
%TotalCodeVA% |
Total Downstream Code Factor Load (VA), Switchboard/Switchgear/Panelboard tab |
%TotalConnAmps% |
Total Downstream Connected Load (Amps), Switchboard/Switchgear/Panelboard tab |
%TotalConnAverageAmps% |
|
%TotalConnkVA% |
|
%TotalConnVA% |
Total Downstream Connected Load (VA), Switchboard/Switchgear/Panelboard tab |
%TotalDemandAmps% |
Total Downstream Demand Load (Amps), Switchboard/Switchgear/Panelboard tab |
%TotalDemandkVA% |
|
%TotalDemandVA% |
Total Downstream Demand Load (VA), Switchboard/Switchgear/Panelboard tab |
%TotalDesignAmps% |
Total Downstream Design Load (Amps), Switchboard/Switchgear/Panelboard tab |
%TotalDesignkVA% |
|
%TotalDesignVA% |
Total Downstream Design Load (VA), Switchboard/Switchgear/Panelboard tab |
%Unit% |
U.S. or Metric |
%Units% |
kVA or Amps |
%UpstreamRating% |
|
%VAUnits% |
Panel Load Units (VA or Amps), Description Tab |
%Voltage% |
Base Voltage (V) |
%Zone% |
Zone |
Grid
These variables display information that appears in the data grids in the schedule.
%BrkrMfg% |
Breaker Manufacturer |
%BrkrStyle% |
Breaker Style |
%CircuitNumber% |
|
%CodeFactorsLoad% |
|
%CodeFactorsLoadFLA% |
|
%CodeFactorsLoadkVA% |
|
%CodekVA% |
|
%CodeVA% |
Panel Summary tab |
%ColumnNum% |
|
%CondRating% |
Conductor Rating (A), Switchboard/Switchgear/Panelboard tab |
%ConnectedLoad% |
|
%ConnectedLoadFLA% |
|
%ConnectedLoadkVA% |
|
%ConnkVA% |
|
%ConnVA% |
Panel Summary Tab |
%Description% |
Load Description, Description tab (for MCC or panel) |
%DemandkVA% |
|
%DemandLoad% |
|
%DemandLoadFLA% |
|
%DemandLoadkVA% |
|
%DemandVA% |
Panel Summary tab |
%DesignkVA% |
|
%DesignLoad% |
|
%DesignLoadFLA% |
|
%DesignLoadkVA% |
|
%DesignVA% |
Panel Summary tab |
%DeviceRating% |
Device Rating (A), Switchboard/Switchgear/Panelboard tab |
%FeederID% |
ID Name, Switchboard/Switchgear/Panelboard tab |
%IntkA% |
Protective Device Int kA, Description tab |
%LoadFacility% |
|
%LoadLocation% |
|
%LoadFloor% |
|
%LoadRef1% |
|
%LoadRef1And2% |
|
%LoadRef2% |
|
%LtPickupAmps% |
|
%LtPickupSetting% |
|
%row% |
Row Number, Description tab |
%RowSpace% |
|
%SectionSpace% |
Section Space, Description tab |
%TripAmps% |
|
%TripMfg% |
Trip Device Manufacturer |
%TripPlug% |
Trip Device Plug |
%TripSensor% |
Trip Device Sensor |
%TripStyle% |
Trip Device Style |
%Type% |
Device, Switchboard/Switchgear/Panelboard tab |