Data Text on the One-line
As you add equipment to your one-line, text appears next to the equipment that describes the it. The table below describes how OnSite determines what text to display on the one-line.
Item |
Text Displayed |
Notes |
---|---|---|
AFD |
Min = Output Frequency Minimum Max = Output Frequency Maximum |
|
ATS |
Voltage Current Rating |
Each bus will have a name that can be used to convert to an EasyPower ATS:
|
Battery |
Amp Hour Rating Battery Resistance |
|
Bus (AC) |
Amp Rating |
|
Bus (DC) |
Continuous Current Rating |
|
Bus Duct |
Ampacity |
|
Busway |
Continuous Current Manufacturer Conductor Material Length |
|
Cable |
Number of Conductors per Phase - Conductor Type - Conductor Size Conductor Material Length [Raceway Type] |
|
Capacitor |
VAR Rating Voltage |
|
CL Reactor |
Impedance kVA Current Rating Reactance |
|
Filter |
Filter Connection Type |
|
Fuse |
Manufacturer (if set) Model (if set) Catalog Number (if set) Current Rating |
Switch state is shown if "Open" |
Generator (AC) |
Rated kVA / MVA PF Power Factor |
|
Generator (DC) |
Output kW Armature Resistance |
|
HV Breaker |
Manufacturer (if set) Type (if set) Catalog Number (if set) Continuous Current |
Switch state is shown if "Open" |
Inverter |
kVA |
DC Top & AC Bottom |
Junction |
|
|
Load (AC) |
Watts VARs |
|
Load (DC) |
Amps |
|
LV Breaker (AC) |
Manufacturer (if set) Type (if set) Catalog Number (if set) Frame / Plug or Trip Amps (if Plug is set, Trip Amps are not displayed) |
Switch state is shown if "Open" |
LV Breaker (DC) |
Manufacturer (if set) Catalog Number (if set) Trip Amps |
Switch state is shown if "Open" |
MCC |
Continuous Current Rating |
|
Motor (AC) |
HP or kW (kW only if HP is not set, blank if neither is set) Type |
|
Motor (DC) |
Output HP Armature Resistance |
|
Motor Overload |
Amp Rating |
|
Panelboard |
Continuous Current Rating |
|
Panel |
Continuous Current Rating |
|
Photovoltaic |
Max Power Rating Voltage at Max Power Current at Max Power |
|
PSS |
Voltage Current Rating |
Each bus will have a name that can be used to convert to an EasyPower ATS:
|
Rectifier |
AC Current Rating |
AC on top, DC on the bottom |
Shunt |
Resistance +j Reactance |
|
Starter |
Size Current Rating |
Switch state is shown if "Open" |
Switch |
Manufacturer (if set) Model (if set) Catalog Number (if set) Current Rating |
Switch state is shown if "Open" |
Switchboard |
Continuous Current Rating |
|
Switchgear |
Continuous Current Rating |
|
Three Winding Transformer |
Primary Self-Cooled Rating / Secondary Self-Cooled Rating / Tertiary Self-Cooled Rating Primary Rated Voltage - Secondary Rated Voltage - Tertiary Rated Voltage |
|
Transmission Line |
Number of Phases - Size Material Length |
|
Two Winding Transformer |
Self Cooled Rating (if set)/(if both set) Forced Cooled or Dual Temp Rating (if set) Primary Rated Voltage - Secondary Rated Voltage Impedance (Z%) % |
|
UPS |
Input kVA |
|
Utility |
Short Circuit (3-Phase) X/R (X/R) Short Circuit (Line-to-Ground) X0/R0 (X0/R0)
|
|
DC Utility |
Short Circuit Current |
|
Zig Zag Transformer |
Impedance Grounding Resistance +j Grounding Reactance |
|