Data Text on the One-line

As you add equipment to your one-line, text appears next to the equipment that describes the it. The table below describes how OnSite determines what text to display on the one-line.

Item

Text Displayed

Notes

AFD

Min = Output Frequency Minimum

Max = Output Frequency Maximum

 

ATS

Voltage

Current Rating

Each bus will have a name that can be used to convert to an EasyPower ATS:

  • Upper left: Source 1
  • Upper right: Source 2
  • Middle bottom: Load

Battery

Amp Hour Rating

Battery Resistance

 

Bus (AC)

Amp Rating

 

Bus (DC)

Continuous Current Rating

 

Bus Duct

Ampacity

 

Busway

Continuous Current

Manufacturer

Conductor Material

Length

 

Cable

Number of Conductors per Phase - Conductor Type - Conductor Size

Conductor Material

Length

[Raceway Type]

 

Capacitor

VAR Rating

Voltage

 

CL Reactor

Impedance kVA

Current Rating

Reactance

 

Filter

Filter Connection Type

 

Fuse

Manufacturer (if set)

Model (if set)

Catalog Number (if set)

Current Rating

Switch state is shown if "Open"

Generator (AC)

Rated kVA / MVA

PF Power Factor

 

Generator (DC)

Output kW

Armature Resistance

 

HV Breaker

Manufacturer (if set)

Type (if set)

Catalog Number (if set)

Continuous Current

Switch state is shown if "Open"

Inverter

kVA

DC Top & AC Bottom

Junction

 

 

Load (AC)

Watts

VARs

 

Load (DC)

Amps

 

LV Breaker (AC)

Manufacturer (if set)

Type (if set)

Catalog Number (if set)

Frame / Plug or Trip Amps (if Plug is set, Trip Amps are not displayed)

Switch state is shown if "Open"

LV Breaker (DC)

Manufacturer (if set)

Catalog Number (if set)

Trip Amps

Switch state is shown if "Open"

MCC

Continuous Current Rating

 

Motor (AC)

HP or kW (kW only if HP is not set, blank if neither is set)

Type

 

Motor (DC)

Output HP

Armature Resistance

 

Motor Overload

Amp Rating

 

Panelboard

Continuous Current Rating

 

Panel

Continuous Current Rating

 

Photovoltaic

Max Power Rating

Voltage at Max Power

Current at Max Power

 

PSS

Voltage

Current Rating

Each bus will have a name that can be used to convert to an EasyPower ATS:

  • Upper left: Source 1
  • Upper right: Source 2
  • Middle bottom: Load

Rectifier

AC Current Rating

AC on top, DC on the bottom

Shunt

Resistance +j Reactance

 

Starter

Size

Current Rating

Switch state is shown if "Open"

Switch

Manufacturer (if set)

Model (if set)

Catalog Number (if set)

Current Rating

Switch state is shown if "Open"

Switchboard

Continuous Current Rating

 

Switchgear

Continuous Current Rating

 

Three Winding Transformer

Primary Self-Cooled Rating / Secondary Self-Cooled Rating / Tertiary Self-Cooled Rating

Primary Rated Voltage - Secondary Rated Voltage - Tertiary Rated Voltage

 

Transmission Line

Number of Phases - Size

Material

Length

 

Two Winding Transformer

Self Cooled Rating (if set)/(if both set) Forced Cooled or Dual Temp Rating (if set)

Primary Rated Voltage - Secondary Rated Voltage

Impedance (Z%) %

 

UPS

Input kVA

 

Utility

Short Circuit (3-Phase)

X/R (X/R)

Short Circuit (Line-to-Ground)

X0/R0 (X0/R0)

 

 

DC Utility

Short Circuit Current

 

Zig Zag Transformer

Impedance

Grounding Resistance +j Grounding Reactance

 

More Information

Dragging Items onto the One-line

 